Calibration
Instrument calibration and repair in the UAE: temperature, pressure, electrical, gas detection, dimensional and mass. On-site or in-lab, with traceable certificates.
ITMAD calibrates and repairs measuring and process-control instruments for industrial, energy, healthcare and aviation clients across the UAE. Calibration is carried out either on site at your facility or in the laboratory, depending on the instrument and the downtime you can accept.
What we calibrate
Temperature Measurement Devices
Instruments are compared against calibrated reference thermometers and dry-block or bath sources at multiple points across the working range, so error is known where you actually use the instrument rather than at a single point. Chambers, cold rooms and transport units are surveyed with multiple sensors to show distribution, not just a spot reading.
- Digital thermometers
- Glass thermometers
- Thermo-hygrometers
- Infrared (IR) thermometers
- Whirling hygrometers
- Thermocouples and RTDs
- Refrigerated transport systems
- Ullage temperature interface detectors
- Temperature gauging systems
- Electrode drying ovens
- Temperature calibrators
- Petroleum gauging thermometers
- Freezer and chiller rooms
Electrical Test Equipment
Calibrated across each function and range in use against a multifunction calibrator, with as-found readings recorded before any adjustment. Safety-related instruments such as high-voltage testers and pinhole detectors are verified at the setpoints you rely on.
- Digital and analogue multimeters
- Ammeters
- Frequency meters
- Earth resistance meters
- Resistance boxes
- Digital and analogue clamp meters
- Voltmeters
- Process meters
- Pinhole detectors
- High-voltage testers
Pressure Instruments
Checked against a dead-weight tester or reference pressure calibrator on both rising and falling pressure, which exposes hysteresis and sticking that a single-direction check misses. Transmitters are verified across the full output span.
- Digital and analogue pressure gauges
- Pressure transmitters
- Vacuum gauges
- Digital manometers
- Airline gauges
Gas Detection Instruments
A bump test confirms the sensor and alarm respond; a full calibration adjusts the span response against certified gas of known concentration. We record response time and verify alarm setpoints.
- Portable multi-gas detectors
- Portable single-gas detectors
- Fixed gas detection systems
- Calibration by gas: carbon monoxide, sulphur dioxide, hydrogen sulphide, oxygen, toxic and flammable gases
Precision and Dimensional Instruments
Verified against gauge blocks, setting rings and reference standards at several points across the measuring range, under controlled temperature conditions, since dimensional measurement is sensitive to thermal expansion.
- Digital and analogue vernier calipers
- Inside and outside micrometers
- Dial gauges
- Height gauges
- Depth micrometers
- Inclinometers
- Try squares
- Measuring tapes
- Bore gauges
- Bevel protractors
Environmental, Force and Mass Instruments
Balances are checked with certified reference weights for repeatability, eccentricity and linearity across the weighing range, not at one load. Torque wrenches are verified against a calibrated torque transducer in the direction of use.
- Lux meters
- Anemometers
- pH meters
- Conductivity meters
- Torque wrenches
- Tachometers
- Weighing balances
- Analytical balances
- Industrial weighing balances
What you receive
- A calibration certificate identifying the instrument, its serial number and the reference standards used
- As-found and as-left readings, so you can see whether the instrument had drifted before adjustment
- Measurement uncertainty stated where applicable
- Pass or fail against your stated tolerance, with immediate notification if an instrument is found out of tolerance
- A calibration label on the instrument showing the calibration and due dates
- Your instrument register updated, where we hold it
Accreditation and traceability
Every calibration is issued with a certificate stating the reference standards used, the measured values, and the measurement uncertainty where applicable. Reference standards are traceable to national and international standards. Where an ISO/IEC 17025 accredited certificate is required, the work is performed through our accredited partner laboratory and the certificate is issued under that laboratory's accreditation. Tell us at enquiry stage whether you need an accredited certificate, as it affects turnaround and cost.
Recalibration intervals
Interval depends on the instrument, its use and your quality system. Annual recalibration is common for general workshop instruments; gas detectors and safety-critical instruments are usually verified far more frequently. We can hold your instrument register and notify you before each due date.
Repairs
Instruments found out of tolerance can be repaired or adjusted and recalibrated in the same visit where parts allow, covering general and process-control equipment.
Why clients choose ITMAD
Our calibration technicians are qualified and experienced in instrumentation, we use internationally recognised reference equipment, and we work to documented procedures. Contact ITMAD with your instrument list for a quotation.